Segment ZVP (GE ViewPoint)

Aus Hl7wiki
Wechseln zu: Navigation, Suche

Spezifikation von GE ViewPoint

aus dem Dokument "ViewPoint Technical Reference Guide" ,
Version 5.4
ViewPoint Software Version 5.6


The ZVP segment is used specifically by ViewPoint to communicate exam related information and the doctors/observers (resources) involved with the specified exam. This segment is required and is non-repeating.

Seq Len Datentyp r/o/c Rep# Element Name Usage
1 10 SI O SET ID – ZVP USAGE: SET ID – ZVP ^ ID of exam ^ record state
2 26 TS R Date / Time of the observation Exam date/time(YYYYMMDDHHmmss)
3 Date / Time of end of observation End of exam date/time(YYYYMMDDHHmmss), only for German USEndo
4 60 XCN O Ordered by code Ordered by code
5 60 XCN O Performed by code Performed by code
6 60 XCN O Responsible observer Sonographer (operator 1)
7 60 XCN O Attending doctor Physician (operator 2)
8 30 ST O HL7ExamType
USAGE: Examination type ( USEndo only)
9 60 XCN O Ordered by facility name Facility name (Ordered by)
11 48 PPN R Message origin User^Department^Computer
Name which generated the message
12 60 XCN O Assistant Assistant