cdaefa:EFA XDS Document Metadata Binding
Version vom 12. März 2013, 23:55 Uhr von Jcaumanns (Diskussion | Beiträge) (Die Seite wurde neu angelegt: „For each document the following set of metadata MUST be provided: {|border=1 cellpadding=4 cellspacing=2 !Slot Name !Binding !Slot Value |- |Id |Attribute |I…“)
For each document the following set of metadata MUST be provided:
Slot Name | Binding | Slot Value |
---|---|---|
Id | Attribute | Identifer of the document. This identifier MUST be the same for <rim:ExtrinsicObject/@id> and <ihe:Document/@id>. |
mimeType | Attribute | … |
objectType | Attribute | MUST be set acc. to section 4.3.1.2 of [IHE IT TF 3] |
Status | Attribute | MUST be "urn:oasis:names:tc:ebxml-regrep:StatusType:Approved" |
creationTime | rim:Slot | MUST be set to the document creation time. At least YYYYMMDD MUST be provided. |
languageCode | rim:Slot | … |
sourcePatientID | rim:Slot | MUST be of the same value as $XDSDocumentEntry.PatientId (see below) |
healthcareFacilityTypeCode | Classification | … |
practiceSettingCode | classification | … |
confidentialityCode | classification | SHOULD always be set to “N”. |
XDSDocumentClassCode | classification | … |
XDSDocumentFormatCode | classification | … |
XDSDocumentEntry.PatientId | External identifier | Equals to the patient identifier that was agreed on upon EFA instantiation (encoded as HL7 v3 II data type) |
XDSDocument.UniqueId | External identifier | MUST refer to the OID of the document that is included within the <ihe:Document> element. |
Other metadata than the ones listed above SHOULD NOT be used and MUST NOT be processed by EFA clients and providers.
German Profile
For EFA implementation within the German healthcare system the following constraints and conventions apply:
- healthcareFacilityTypeCode MUST use the respective Value Set defined by gematik