2.16.840.1.113883.5.83/static-2011-03-15

Aus Hl7wiki
Version vom 15. November 2011, 08:37 Uhr von ADbot (Diskussion | Beiträge) (Automated TermBot page content)
Wechseln zu: Navigation, Suche
Hinweis zu dieser Seite

Kodesystem ObservationInterpretation

Beschreibung

One or more codes specifying a rough qualitative interpretation of the observation, such as "normal", "abnormal", "below normal", "change up", "resistant", "susceptible", etc. OpenIssue:
           Description copied from Concept Domain of same name. Must be verified. Note also that this might be identical to the V2 code system of interpretation codes (formerly Abnormal Flags in
older versions).

Aktuelle Version

Code System Name Code System Id Effective date
ObservationInterpretation 2.16.840.1.113883.5.83 2011-03-15
Level/Type Code Kurzbezeichnung Beschreibung
0-A _GeneticObservationInterpretation (en-US) GeneticObservationInterpretation
Codes that specify interpretation of genetic analysis, such as "positive", "negative", "carrier", "responsive", etc.
1-L Carrier (en-US) Carrier
Description: The patient is considered as carrier based on the testing results. A carrier is an individual who carries an altered form of a gene which can lead to having a child or offspring in future generations with a genetic disorder.
0-A _ObservationInterpretationChange (en-US) ObservationInterpretationChange
Change of quantity and/or severity. At most one of B or W and one of U or D allowed.
1-L B (en-US) better
Better (of severity or nominal observations)
1-L D (en-US) decreased
Significant change down (quantitative observations, does not imply B or W)
1-L U (en-US) increased
Significant change up (quantitative observations, does not imply B or W)
1-L W (en-US) worse
Worse (of severity or nominal observations)
0-A _ObservationInterpretationExceptions (en-US) ObservationInterpretationExceptions
Technical exceptions. At most one allowed. Does not imply normality or severity.
1-L < (en-US) low off scale
Below absolute low-off instrument scale. This is statement depending on the instrument, logically does not imply LL or L (e.g., if the instrument is inadequate). If an off-scale value is also low or critically low one must also report L and LL respectively.
1-L > (en-US) high off scale
Above absolute high-off instrument scale. This is statement depending on the instrument, logically does not imply LL or L (e.g., if the instrument is inadequate). If an off-scale value is also high or critically high one must also report H and HH respectively.
0-A _ObservationInterpretationNormality (en-US) ObservationInterpretationNormality
Normality, Abnormality, Alert. Concepts in this category are mutually exclusive, i.e., at most one is allowed.
1-S A (en-US) Abnormal
Abnormal (for nominal observations, all service types)
2-S AA (en-US) Abnormal alert
Abnormal alert (for nominal observations and all service types)
0-L HH (en-US) High alert
Above upper alert threshold (for quantitative observations)
0-L LL (en-US) Low alert
Below lower alert threshold (for quantitative observations)
2-S H (en-US) High
Above high normal (for quantitative observations)
0-L HH (en-US) High alert
Above upper alert threshold (for quantitative observations)
2-S L (en-US) Low
Below low normal (for quantitative observations)
0-L LL (en-US) Low alert
Below lower alert threshold (for quantitative observations)
1-L N (en-US) Normal
Normal (for all service types)
0-A _ObservationInterpretationSusceptibility (en-US) ObservationInterpretationSusceptibility
Microbiology: interpretations of minimal inhibitory concentration (MIC) values. At most one allowed.
1-L I (en-US) intermediate
Intermediate
1-L MS (en-US) moderately susceptible
Moderately susceptible
1-L R (en-US) resistent
Resistent
1-L S (en-US) susceptible
Susceptible
1-L VS (en-US) very susceptible
Very susceptible
0-S EX (en-US) outside threshold
Definition:The observation/test result is interpreted as being outside the inclusion range for a particular protocol within which the result is being reported. Example:A positive result on a Hepatitis screening test.
1-L HX (en-US) above high threshold
Definition:The numeric observation/test result is interpreted as being above the high threshold value
               for a particular protocol within which the result is being reported. Example:An ALT (SGOT) result above a protocol-defined threshold value of 2.5 times the upper limit of normal based
on the subject's sex and age.
1-L LX (en-US) below low threshold
Definition:The numeric observation/test result is interpreted as being below the low threshold value for a particular protocol within which the result is being reported. Example:A Total White Blood Cell Count falling below a protocol-defined threshold value of 3000/mm^3
0-A ObservationInterpretationDetection (en-US) ObservationInterpretationDetection
Description: The specializations of this concept indicate the presence or absence of an
               analyte in a test or of a sign in a clinical observation. In keeping with laboratory data processing practice, these codes provide a categorical interpretation of the "meaning" of the
quantitative value for the same observation.
1-L IND (en-US) Indeterminate
Description: The value of this observation does not allow interpretation as to whether or not the analyte or sign in question is present.
1-L NEG (en-US) Negative
Description: The value of this observation is interpreted as showing that the analyte or sign in question is not present.
1-L POS (en-US) Positive
Description: he value of this observation is interpreted as showing that the analyte or sign in question is present.

Verwendung in Value Sets

Zusammenstellung anderer Versionen dieses Kodesystems

(bisher keine weiteren Angaben)